Compressed air efficiency: measure, fix, and sustain gains

Measure compressor efficiency to track energy savings potential
Measure compressor efficiency to track energy savings potential

Compressed air efficiency is rarely limited by the compressor alone. In most plants, the real losses sit in leaks, excessive pressure, unstable control, and poor air quality. The fastest route to savings is a measurement-first approach that links m3n/hr to kW, so you can prioritise actions that pay back in months. If you already run ISO 50001, this is also the simplest way to turn utilities data into defensible energy performance indicators (EnPIs).

Start by planning energy monitoring that covers both demand side and supply side. When you can see demand, pressure, and compressor power on one timeline, the waste becomes obvious and the business case becomes easy.

Compressed air efficiency: why it matters in kWh and uptime

Compressed air is one of the most expensive utilities per unit of energy delivered to the point of use. That is why small inefficiencies scale quickly across 8000 h/year production schedules. In practice, many industrial sites can achieve a 10/20% efficiency improvement with structured measurement and targeted fixes.

Savings potential varies by site. A realistic band for total cost reduction is often 10/50%, depending on leak level, pressure strategy, compressor control, and how stable demand is. The key is to convert findings into actions that reduce kW (energy) without creating pressure drops that risk scrap or downtime.

Two financial levers matter for energy and plant managers: reducing specific energy (kWh/m3n) and avoiding unplanned stops. Lower demand reduces compressor running hours. Better pressure stability reduces nuisance trips and quality issues. Both benefits are measurable when you log flow, pressure, and power together.

What to measure and where to place sensors

To manage compressed air, measure what you can control. At minimum, log system flow, pressure, and compressor electrical power. Add dew point to monitor humidity levels to prevent issues with product quality and e.g. corrosion. Use normalised flow units (m3n/hr) so you can compare apple with apple results using the same reference conditions.

Flow (m3n/hr, l/min): Place a main meter on the main header downstream of dryers and filters to capture total plant demand. Add sub-metering on production areas and high-use areas (packaging lines, moulding, blast air, pneumatic conveying). Sub-metering enables cost allocation and makes leak hunting faster because you can see which area drives base load.

Power (kW, kWh): Measure each compressor with a three-phase power meter. Power alone is not enough. Flow alone is not enough. Together, they reveal specific power (kW per m3n/hr) and allow you to quantify improvement after each change.

Pressure (bar(g)): Log pressure at the compressor room header and at the most critical point of use. The difference is your distribution pressure drop. Even a small pressure drop can trigger higher setpoints, which increases energy use. In addition, monitor critical maintenance points like filters to avoid a large pressure drop over clogged filters.

Dew point (C): Dew point indicates dryness and dryer performance. A drifting dew point can signal desiccant issues, purge losses, or a failing refrigeration dryer. It also supports compliance for sensitive sectors such as food and pharma. If you need guidance on dew point, we recommend watching this free dew point webinar.

Mass vs volumetric flow: For efficiency work, you want normalised (mass-related) flow because energy correlates to the amount of air, not the compressed volume in the pipe. Normalised flow (m3n/hr) removes the effect of operating pressure and temperature and makes your KPIs stable.

Safety note: Always follow plant safety protocols and depressurize the system before installation, unless using a hot-tap tool specifically designed for installation under pressure.

A step-by-step plan: baseline/install/analyse/act/review

Step 1 – Baseline: Log flow, pressure, and compressor power continuously. Capture data also in weekends and planned downtime period. That exposes base load and leak-driven demand.

Step 2 – Install meters at the right points: Confirm straight pipe requirements and avoid disturbed flow near bends and valves. Put the main flow meter where it represents total demand. For more granular compressor insights, it is recommended to add a flow meter at the discharge of each individual compressor. Add power meters to measure compressor consumption. . Add a pressure sensor at the critical end-of-line user.

Step 3 – Centralise data in one view: Bring measurements into VPVision so production, maintenance, and energy managers can see the same trends. Use tags for areas and compressors to speed up reporting for ISO 50001 audits.

Step 4 – Analyse with simple questions: Some examples: What is minimum flow during non-production? How often does pressure sit above the required value? Do compressors run unloaded for long periods? Does demand spike after shift changes?

Step 5 – Execute actions in order of ROI: Start down stream. Get rid of artificial demand. Fix the biggest leaks first. Address distribution restrictions and inappropriate uses such as open blowing. Then reduce pressure safely. Works you way up to the compressor room. After downstream optimization, optimize the compressor room, like the compressor control (sequencing, load/unload settings, or variable speed strategy).

Step 6 – Review and lock in the gain: Recalculate KPIs weekly for the first month. Then move to monthly reviews with alarms for drift. Sustainable savings come from holding the new baseline, not from a one-off audit.

3) Pressure optimisation scenario: If data confirms end-of-line pressure is stable, you can reduce header setpoint by e.g. 0.5 bar(g). Many systems see a measurable energy reduction and a lower leak rate because leak flow rises with pressure. Use your logged kW and m3n/hr to verify the actual site effect and avoid assumptions. Production performance and stability are key, but don’t forget that 1 bar pressure reduction, saves 7% of energy. Therefore, if you can lower your pressure, it is a significant cost saver.

This type of ROI calculation is simple, transparent, and easy to explain to finance. It also creates a clear target: reduce base load first, then improve control efficiency.

KPIs that keep improvements from slipping back

Choose KPIs you can calculate automatically and review fast. Tie each KPI to a corrective action and an owner.

  • Specific energy (kWh/m3n): primary efficiency KPI; track continuously and by operating mode.
  • Leak indicator (% of total): use minimum flow during non-production as a proxy; trend it after leak rounds. Watch out for sudden jumps in consumption, this could indicate a huge new leak occurred.
  • Pressure stability (bar(g)): standard deviation at the critical user; instability often costs scrap and trips.
  • Pressure drop (bar(g)): header minus end-of-line; rising drop points to clogged filters or undersized piping.
  • Dew point (C): keeps air quality compliant and highlights dryer inefficiency or purge losses.

For ISO 50001 document: baseline period, production context, and changes implemented. Then use the same KPIs as your EnPIs and keep them visible for operations.

Compressed air efficiency improves when you stop guessing and start managing one set of shared numbers: flow, pressure, temperature, power, and (when relevant) dew point. Measure a baseline, execute the highest-ROI fixes first, and then use KPIs to prevent drift. If you want to quantify your next project quickly, start with VPInstruments measurement tools and a simple review rhythm.

Book a Demo of VPVision to see how plug-and-play compressed air monitoring turns kW and m3n/hr into actions your team can execute and finance can approve.

Where should the main flow meter go?

Place it where it represents total plant demand, typically downstream of air treatment and before major branches. Avoid locations with heavy turbulence or two-phase flow from poor draining.

Can we install flow meters under pressure?

Insertion type flow meters can be installed under pressure by using hot tapping tools and ball valves. For in-line flow meter often the system needs to be depressurized locally. Always follow plant safety protocols as working with compressed air can be dangerous.

Do we need dew point measurement for efficiency?

A dew point sensor is useful for efficiency tracking, but even more important to reduce maintenance costs and even product loss. It is highly recommended to measure. Dew point is also a clear compliance metric in regulated sectors.

How do we integrate with PLC or SCADA?

Use standard industrial communication (for example Modbus). Focus on getting consistent timestamps and units (m3n/hr, bar(g), kW) so comparisons remain valid.

How often should meters be checked?

Include meters in your maintenance plan. Verify readings against expected operating ranges after major shutdowns, filter changes, or compressor service.