Home » Shop » VPFlowScope In-line 3/8″

VPFlowScope In-line 3/8″

With the VPFlowScope In-line 3/8”, you have the perfect tool to measure low flows of compressed air and oxygen at point of use. With the measurement insights, you can reduce your consumption, allocate costs, and optimize your compressed air/ oxygen system.

With the patented Thermabridge™ technology, the VPFlowScope In-line 3/8” enables you to measure flow, total flow and temperature simultaneously. The built-in display shows the actual and total flow, and you can use the Modbus and analog 4..20 mA outputs to interface with VPVision or other monitoring systems.

Download brochure


Or go to our webshop.

Description

“For manufacturers using compressed air VPInstruments provides excellent measurement solutions including flow meters, dew point sensors and monitoring systems that allow you to identify and eliminate energy losses in your factory. Kudos to the VPInstruments Team.”

 – Mathew Waita, Ren Engineering Solutions

Your compressed air meter for low flows

With the VPFlowScope In-line 3/8”, you have the perfect tool to measure low flows of compressed air and oxygen at the point of use. With the measurement insights, you can reduce your consumption, allocate costs, and optimize your compressed air/ oxygen system.

With the Thermabridge™ technology, the VPFlowScope In-line 3/8” enables you to measure flow, total flow, and temperature simultaneously. The built-in display shows the actual and total flow, and you can use the Modbus and analog 4..20 mA outputs to interface with VPVision or other monitoring systems.

Features/ Benefits of this flow meter

  • Measures flow, total flow, and temperature simultaneously
  • Thermabridge™ technology for dry, clean gas measurements
  • For compressed air and/or oxygen
  • RS485 (Modbus RTU) + 4..20 mA output
  • 2-line TFT display with real-time information and configuration keys
  • Power and communication LEDs
  • Easy to install and compact size

Applications of the VPFlowScope In-line 3/8″

  • Point of use in compressed air systems
  • Output of oxygen generators
  • Consumption measurement
  • Leakage measurement
  • Cost allocation and measuring your distribution network
Specifications

Specifications

PRELIMINARY

Flow range 2.15..50 l/min | 0.09..1.77 CFM
Accuracy 5% of full scale under calibration conditions
Temperature 20 .. 32 °C | 68 .. 89.6 °F
Reference conditions 20 °C, 1000 mbar | 68 °F, 14.50 psi
Gas types Oxygen, compressed air
Diameter 3/8″
Display type 1.8″ TFT for real-time flow and total flow readout
Outputs RS485 (Modbus RTU) | 4 … 20 mA
Electrical connection M8 5-pin female connector
LED status LED indicators for power and communication
Material Brass, polycarbonate
Pressure rating 0 … 10 bar gauge | 0 … 150 psi gauge
Power supply 14 … 24 VDC
Certification CE EN 60950-1, EN 61326-1, EN 61000-3-2, EN 61000-3-3, EN 61326-1
Mounting connection Mount between pipe ends using Hylok SICMC-6-6G
Brochure

Brochure

Download all

Brochure

pdf

Brochure VPFlowScope In-line_3-8_US

Size: 185.12 KB
Hits: 112
Date added: 15-05-2025
Preview Downloaden
pdf

Brochure VPFlowScope In-line_3-8_EN

Size: 184.31 KB
Hits: 125
Date added: 15-05-2025
Preview Downloaden

Manual

Manual

Download all

Manual

pdf

Manual VPFlowScope In-line 3-8 inch_EN

Size: 605.38 KB
Hits: 110
Date added: 15-05-2025
Preview Downloaden